Laboratory equipment for Indian and global buyers
+91 88262 76000info@laboteck.com
Analytical Instruments

Integrated Distillation Apparatus

An integrated distillation apparatus runs several laboratory distillations at once with automatic heating, cooling and end point control. Laboteck's Optima 6 and R6 units have six independently controlled 500 W positions, far infrared ceramic heating, closed loop cooling and weighing or timed end point detection. An Optima M4/M6 version is made for sulfur dioxide tests.

  • Six independently controlled positions, 500 W each
  • Far infrared ceramic heating with no open flame
  • Built in or external closed loop cooling, no tap water needed
  • Weighing end point (0.1 g) or timed distillation

Key Features of the Integrated Distillation Apparatus

  • Six independently controlled positions, 500 W each
  • Far infrared ceramic heating with no open flame
  • Built in or external closed loop cooling, no tap water needed
  • Weighing end point (0.1 g) or timed distillation
  • Anti suck back valve and automatic outlet lock
  • One click self cleaning and touchscreen control

Integrated Distillation Apparatus Technical Specifications

Parameter Optima 6/6+ R6 Full Glass Optima M4/M6/MH6
Positions 6 6 4 or 6
Heating Far infrared ceramic, 500 W per channel Far infrared ceramic, 500 W per channel Far infrared ceramic
Cooling Built in or external compressor, closed loop Closed loop External cold water, closed loop
End point Weighing (0.1 g) or timed Weighing, timed, or weighing + timed Timed
Control External LCD touchscreen 7 inch touchscreen Touchscreen
Special One click self cleaning, anti suck back Glass one way valve, full glass view Nitrogen purge, anti backflow, stirring

Specifications can vary by model and configuration. The final specification is confirmed in your quotation.

Applications

  • Water and wastewater: cyanide, phenol, ammonia nitrogen
  • Environmental testing laboratories
  • Food sulfur dioxide tests
  • Chemical and research labs

Standards and Compliance

Multi position distillation is used to prepare samples for standard methods for cyanide, volatile phenol, ammonia and sulfur dioxide. Follow the method you are accredited for.

How to Choose the Right Integrated Distillation Apparatus

Choose Optima 6/6+ for routine water analysis, R6 when you want full glass visibility, and Optima M4/M6/MH6 for sulfur dioxide in food.

Frequently Asked Questions

What is an integrated distillation apparatus used for?

It is used to distil several samples at the same time to separate volatile analytes such as cyanide, phenol, ammonia or sulfur dioxide before measurement. Heating, cooling and end point detection are automatic, so results are consistent and the operator saves time.

How many samples can be distilled at once?

The Optima 6/6+ and R6 run six positions at once, and the sulfur dioxide model runs four or six. Each position is controlled independently, so different samples or settings can run side by side.

Does it need tap water for cooling?

No. Cooling runs in a closed loop using built in or external compressor refrigeration, so there is no continuous tap water use and condensation works even in warm conditions.

What is the price of Integrated Distillation Apparatus in India?

The Integrated Distillation Apparatus price depends on the model, size, configuration and accessories you choose, so Laboteck quotes each requirement individually instead of publishing a fixed price list. Send your requirement through the quote form or WhatsApp and you will receive a quotation in INR with GST, delivery time and warranty terms.

Do you export distillation apparatus?

Yes. Laboteck supplies distillation apparatus to laboratories across India and exports to buyers worldwide. Share the model or size you need, quantity, power supply and destination country, and our team will reply with a quote in INR or USD, delivery time and shipping options.