Automated Parallel Concentrator
An automated parallel concentrator evaporates solvent from many samples at once using heated water bath and nitrogen flow, and stops each sample at a…

A fully automatic chemistry analyzer runs clinical biochemistry tests such as glucose, liver and kidney panels on serum and plasma without manual pipetting. Laboteck supplies the YS-200 and YS-600 with 200 and 600 tests per hour, plus a compact veterinary analyzer and a semi automatic model for smaller labs.
| Model | Ys-200 | |
|---|---|---|
| Overall Performance | Throughput | 200Tests/Hour |
| Analysis Method | End-point, Fixed-time, Rate (Kinetic), Turbidimetry | |
| Sample & Reagent Unit | Sample Positions | 49 sample positions |
| Reagent Positions | 56 reagent positions | |
| Sample Volume | 2~70μl | |
| Reagent Volume | 20~350μl | |
| Probe | Teflon coating, within-collision function, liquid level detection function. | |
| Probe washing | Automatic washing of interior and exterior | |
| Reagent Cooling | Refrigerated tray with independent switch | |
| Reaction System | Temperature Control | 37±0.1℃, real-time monitor |
| Cuvettes | 120 reusable cuvettes, optical length 6mm | |
| Mixer Probe | Independent stirring | |
| Washing | Automatic cuvettes washing | |
| STAT function | YES | |
| Optical System | Light Source | 12V/30W halogen lamp |
| Spectrophotometry | Post-spectral spectrophotometry | |
| Wavelength | 340,405,450,510,546,578,630,700nm | |
| Absorbance | 0~3.0Abs | |
| Calibration & QC | Calibration | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Logarithm, Logit-4P, Logit-5P |
| Quality Control | Real-time QC, Westgard multi rule, Cumulative sum check, Twin Plot(2D) | |
| Data Management | Software | Windows 7/8/10, LIS system available |
| LIS System | Bi-direction, support HL7 protocol | |
| Interface | LAN port access | |
| Printer | External, multiple reporting modes are available | |
| Working Conditions | Power Supply | AC220V±10%, 60/50Hz,, 110V±10%, 60Hz, 300W |
| Temperature | 10~30℃ | |
| Water Consumption | Deionized water:5L/H | |
| Humidity | 30-80% | |
| Size & Weight | External Size (W*D*H) | 950*612*510mm |
| Net Weight | 75kg | |
| Package Size(W*D*H) | 1118*728*1151mm | |
| Gross Weight | 130kg | |
| Model | Ys-600 | |
|---|---|---|
| Overall Performance | Throughput | 600Tests/hour |
| Analysis Method | End-point, Fixed-time, Rate, Two-point, Turbidimetry | |
| Sample & Reagent System | Sample Positions | 90sample positions, built-in barcode system available |
| Reagent Positions | 180refrigerated reagent positions(R1:45 & R2:45) | |
| Sample Volume | 2~70μl | |
| Reagent Volume | 20~350μl | |
| Probe | Teflon coating ,with anti-collision function, liquid level detection function | |
| Probe Washing | Automatic washing of interior and exterior | |
| Reagent Cooling | Refrigerated tray with independent switch | |
| Reaction System | Temperature Control | 37±0.1℃, real-time monitoring |
| Cuvettes | 120reusable cuvettes, optical length 6mm | |
| Mixer Probe | Independent stirring | |
| Washing | Automatic cuvettes washing | |
| STAT function | YES | |
| Optical System | Light Source | 12V/30W halogen lamp |
| Spectrophotometry | Post-spectral spectrophotometry | |
| Wavelength | 340,405,450,510,546,578,630,700nm | |
| Absorbance | 0~3.0Abs | |
| Calibration & QC | Calibration | 1-point, 2-point and multipoint, factor, Spline Logit-4P, Logit-5P |
| Quality Control | Inserting quality control at random | |
| Data Management | Software | Windows 7/8/10 |
| LIS System | Available | |
| Interface | LAN port access | |
| Printer | External, multiple reporting modes are available | |
| Working Conditions | Power Supply | AC220V±10%,50/60Hz, 110V±10%,60Hz, 300W |
| Temperature | 10~30℃ | |
| Water Consumption | Deionized water:15L/H | |
| Humidity | 30-80% | |
| Size & Weight | External Size (W*D*H) | 1167*780*1016mm |
| Net Weight | 216kg | |
| Package Size (W*D*H) | 1348*928*1399mm | |
| Gross Weight | 290kg | |
| Accessory Package Size | 678*624*548mm | |
| Accessory Gross Weight | 70kg | |
| Model | YS-100vet |
|---|---|
| Sample Type | Whole blood, serum, plasma |
| Sample Volume | 100ul |
| Bar Code | Two-dimensional bar code |
| Testing Time | 12 minutes per sample |
| Reaction Temperature | 37℃±0.2℃ |
| QC & Calibration | Real-time full-automatic finish |
| Working Condition | Temperature: 10-32℃ Humidity: <90% |
| Light Source | 12V/20W, halogen lamp (average lifespan>2500 hours) |
| Input Voltage | AC100-240V, 50-60Hz (DC power supply optional) |
| Power Consumption | 70Watt |
| Display | 7 inches TFT touch screen |
| Storage | >100,000 results |
| Printer | 4 Usb, 1 Rs232 |
| Net Weight | 5KG |
| Dimensions (W*D*H) | 21*28*31cm |
| Package Size(W*D*H) | 35*28*40mm |
| Gross Weight | 6.5kg |
| Model | Laboteck – Silver Plus |
|---|---|
| Reading Cuvette | Both through the cell and direct reading cuvette |
| Incubating Positions | 20 incubation positions |
| Photometric System | Light source: 6V, 10W halogen lamp |
| Filters: 340,405,492,510,546,578,620nm, 2 more open filter positions, ±2nm pass-hand | |
| Wavelength accuracy:±2nm | |
| Measuring System | Measuring range: 0~2.500 OD |
| Photometric linearity:±2% from 0 to 2.000 OD | |
| Photometric accuracy:±2% from 0 to 2.001 OD | |
| Drift<0.005 OD | |
| Carry over≤1% | |
| Incubator Temperature Control | Rt+25℃, 30℃, 37℃ |
| Precision: ±0.1℃ | |
| Display/Keyboard | Touch Screen |
| Printer | Built-in thermal printer |
| Interface | Rs-232, Usb |
| Power Supply | AC110/220V±10% 60/50Hz, |
| External Size (W*D*H) | 340*380*180mm |
| Package Size (W*D*H) | 575*490*350mm |
| Gross Weight | 19Kg |
Specifications can vary by model and configuration. The final specification is confirmed in your quotation.
Clinical analyzers are medical devices in many countries. Confirm local registration requirements before purchase, and run daily quality control with commercial control sera.
Choose the semi automatic model for low daily volumes, the YS-200 for small and medium labs, and the YS-600 for high volume hospital laboratories.
It is a clinical laboratory instrument that automatically pipettes samples and reagents, mixes them, incubates them at 37°C and reads the reaction photometrically. It reports biochemistry results such as glucose, urea, creatinine, liver enzymes and lipids with little manual work.
The YS-200 runs up to 200 photometric tests per hour and the YS-600 up to 600 tests per hour. Actual throughput depends on the test menu and how many tests each sample needs.
Yes. Both fully automatic models have LAN connection and LIS support, and the YS-200 supports bi directional HL7 communication, so orders and results can move between the analyzer and the LIS.
The Fully Automatic Chemistry Analyzer price depends on the model, size, configuration and accessories you choose, so Laboteck quotes each requirement individually instead of publishing a fixed price list. Send your requirement through the quote form or WhatsApp and you will receive a quotation in INR with GST, delivery time and warranty terms.
Yes. Laboteck supplies chemistry analyzers to laboratories across India and exports to buyers worldwide. Share the model or size you need, quantity, power supply and destination country, and our team will reply with a quote in INR or USD, delivery time and shipping options.
An automated parallel concentrator evaporates solvent from many samples at once using heated water bath and nitrogen flow, and stops each sample at a…
An automatic Kjeldahl nitrogen analyzer distils and titrates digested samples to measure nitrogen and calculate protein content. Laboteck offers five models covering 0.1 to…
An automatic potentiometric titrator adds titrant and tracks the electrode potential to find the end point of a titration without a colour indicator. Laboteck…
A benchtop ion meter reads ion selective electrodes to measure the concentration of a specific ion, such as fluoride, chloride or nitrate, in water…